by smercurio_fc <x@[EMAIL PROTECTED]
>
May 12, 2008 at 12:10 PM
You basically need to look at the Type Descriptor information which you can
get by converting the control to a variant, or you can use the Flatten To
Sting function, with it changed to "Convert 7.x Data". Or, the easiest
way is to use the OpenG function Get TDEnum From Data.
Example_VI.png: